• Delivery RET-10in stock
  • Warranty 5 years
  • Price on-demand

The RET-10 block allows high-precision scaling of one of the output current channels of RETOM-51(61) with the factors 10, 5 and 0,1, thus providing for the possiblilty of testing with the wider range of currents and loads.

From the user's standpoint, RET-10 block allows to widen the technical application of RETOM-51(61) considerably, namely:

  • to bring the maximal output current to 200 A,
  • to lower the minimal output current to 1 mA,
  • to issue current in the range of 2 A at high-impedance loads of up to 65 Ohm.

The current converter block RET-10 is made on the basis of magnetic core from nanocristallic alloy with rare-earth components.

 
TECHNICAL SPECIFICATIONS

Number of outputs

3

Rated power, VA

200

Power in the mode of increased load, VA

400

Maximal power in repeated short-time mode, VA

750

Current transformation factors, Kt= I1/I2

0,1

5

10

Maximal output current for Kt conversion factors, respectively, A:

200

4

2

Load impedance range within the limit of nominal power, Ohm

0,00625

16

62,5

Load impedance range in increased load mode, Ohm

0,0125

32

125

Output current within the limit of nominal power, A

(0,997... 1,003) I1/KT

Output current in increased load mode, A

(0,990...1,010)  I1/KT

Error of output current at the change of primary current, where I is the value of current in the primary winding

± 0,04 (20/I -1)

Frequency range, Hz

40 - 600

Error of phase, °

±[40 + 0,045 (20/I-1)]

Maximal non-linear distortions factor,%

1

Continuous load time at the maximum output power :

- from cold state (20 °C), no less then (minutes)

- during repeated testing, length of "on" time =30%, no less then (min)

 

20

10

 

Electric resistance of isolation between:

- galvanically separated current-conducting details, MOhm, no less then

- current-conducting details and cover, MOhm, no less then

 

20

20

Testing voltage between:

- galvanically separated current-conducting details,, kV, maximum

- current-conducting details and cover, kV, maximum

 

2

2

Overall dimensions, mm, maximum

345 x 265 x 110

Weight, kg, maximum

9

OPERATING CONDITIONS

External temperature range, °C

- 20 ... + 50

Normal temperature, °CC

20±2

Maximal humidity at 25 °C, %

80

Maximal height above sea level, m

1000

Operating conditions group, according to GOST17516.1

М23

Level of protection:

- on the frame

- on the external contacts

 

IP20

IP00

Class of protection against affection from electric current according to GOST 12.2.007.0

0I

to top